The charging method of both batteries is a constant current and then a constant voltage (CCCV), but the constant voltage points are different. The nominal voltage of a lithium iron phosphate battery is 3.2V, and the charging cut-off voltage is 3.6V. The nominal voltage of ordinary lithium batteries is 3.6V, and the charging cut-off voltage is 4.2V.
The positive electrode material of lithium iron phosphate batteries is generally called lithium iron phosphate, and the negative electrode material is usually carbon. On the left is LiFePO4 with an olivine structure as the battery’s positive electrode, which is connected to the battery’s positive electrode by aluminum foil.
Constant current discharge is the discharge of the same discharge current, but the battery voltage continues to drop, so the power continues to drop. Figure 5 is the voltage and current curve of the constant current discharge of lithium-ion batteries.
The nominal voltage of a lithium iron phosphate battery is 3.2V, and the charging cut-off voltage is 3.6V. The nominal voltage of ordinary lithium batteries is 3.6V, and the charging cut-off voltage is 4.2V. Can I charge LiFePO4 batteries with solar? Solar panels cannot directly charge lithium-iron phosphate batteries.
Solar panels cannot directly charge lithium-iron phosphate batteries. Because the voltage of solar panels is unstable, they cannot directly charge lithium-iron phosphate batteries. A voltage stabilizing circuit and a corresponding lithium iron phosphate battery charging circuit are required to charge it.
The discharge curve basically reflects the state of the electrode, which is the superposition of the state changes of the positive and negative electrodes. The voltage curve of lithium-ion batteries throughout the discharge process can be divided into three stages