Charge–discharge cycle life test Ninety-six 18650-type lithium iron phosphate batteries were put through the charge–discharge life cycle test, using a lithium iron battery life cycle tester with a rated capacity of 1450 mA h, 3.2 V nominal voltage, in accordance with industry rules.
At a room temperature of 25 °C, and with a charge–discharge current of 1 C and 100% DOD (Depth Of Discharge), the life cycle of tested lithium iron phosphate batteries can in practice achieve more than 2000 cycles , .
Lithium iron phosphate batteries can be used in energy storage applications (such as off-grid systems, stand-alone applications, and self-consumption with batteries) due to their deep cycle capability and long service life.
Analysis of the reliability and failure mode of lithium iron phosphate batteries is essential to ensure the cells quality and safety of use. For this purpose, the paper built a model of battery performance degradation based on charge–discharge characteristics of lithium iron phosphate batteries .
Part of the charge–discharge cycle curve of lithium iron battery. According to the testers record, ninety-six battery samples failed (when the battery capacity is less than 1100 mA h). The cycles are listed in Table 2 in increasing order, equivalent to the full life cycle test.
For this purpose, the paper built a model of battery performance degradation based on charge–discharge characteristics of lithium iron phosphate batteries . The model was applied successfully to predict the residual service life of a hybrid electrical bus.