The lead acid storage battery is formed by dipping lead peroxide plate and sponge lead plate in dilute sulfuric acid. A load is connected externally between these plates. In diluted sulfuric acid the molecules of the acid split into positive hydrogen ions (H +) and negative sulfate ions (SO 4 − −).
The construction of a lead acid battery cell is as shown in Fig. 1. It consists of the following parts : Anode or positive terminal (or plate). Cathode or negative terminal (or plate). Electrolyte. Separators. Anode or positive terminal (or plate): The positive plates are also called as anode. The material used for it is lead peroxide (PbO 2).
The lead acid battery diagram is This container part is constructed with ebonite, lead-coated wood, glass, hard rubber made of the bituminous element, ceramic materials, or forged plastic which are placed on the top to eliminate any kind of electrolyte discharge.
In this article we will discuss about the working of lead-acid battery with the help of diagram. When the sulphuric acid is dissolved, its molecules break up into hydrogen positive ions (2H +) and sulphate negative ions (SO 4– –) and move freely.
Lead peroxide (PbO 2). Dilute sulfuric acid (H 2 SO 4). The positive plate is made of lead peroxide. This is dark brown, hard and brittle substance. The negative plate is made of pure lead in soft sponge condition. Dilute sulfuric acid used for lead acid battery has a ratio of water : acid = 3:1.
Construction, Working, Connection Diagram, Charging & Chemical Reaction Figure 1: Lead Acid Battery. The battery cells in which the chemical action taking place is reversible are known as the lead acid battery cells. So it is possible to recharge a lead acid battery cell if it is in the discharged state.