Install CATCH Solar Relay as per the circuit diagram below. • Power the device up and connect to it using the CATCH Power Configuration App on your phone or tablet. The Configuration App uses Bluetooth to communicate with the CATCH Solar Relay. Page 6 240VAC, with a maximum coil current of 4A.
Page 12 INSTALLATION – Configuration CATCH Solar Relay is configured over a Bluetooth connection using the CATCH Configurator App. The CATCH Configurator app is available on the Apple App Store and Google Play. Scanning for new Devices When the Configurator opens it will automatically start searching for any Catch Power devices.
Contactor selection should be made based on load requirements. The solar relay requires the coil voltage to be 240VAC, with a maximum coil current of 4A. If the export control feature of CATCH Solar Relay is required then the CT must be installed. The CT can be positioned anywhere in the installation that sees all loads and solar.
Maximum wire size for the Solar Relay is 2.5mm2. Contactor selection should be made based on load requirements. The solar relay requires the coil voltage to be 240VAC, with a maximum coil current of 4A. If the export control feature of CATCH Solar Relay is required then the CT must be installed.
Page 11 INSTALLATION – Power Up There are 3 LEDs on the Solar Relay that provide indicators on what is happening. Power: Green indicates power is applied to the unit, and the unit is functional. Load On: When green it means power has been applied to the Active Out port.
Tighten the screw of the display assembly. Insert the plug from the multifunction relay ribbon cable into the left-hand pin connector on the display assembly. You have to press apart the lock hooks on the pin connector in order to insert the plug. After inserting the plug, the lock hooks close.